
Central venous pressure monitoring and mortality: What was neglected ...
Oct 23, 2020 · We are interested in the recent published article about the association between central venous pressure (CVP) monitoring and mortality for ICU patients with sepsis [1]. The study provides …
Comments on “Right ventricular failure in septic shock ...
Apr 9, 2021 · The authors defined right ventricular failure as the association of RV dilatation (RV/LVEDA < 0.6) and increased central venous pressure (CVP ≥ 8 mmHg). They showed that this definition of …
Comment on: Association between intrarenal venous flow from …
Aug 29, 2023 · With great interest we read the recent article by Fujii et al. [1], which brings forth valuable insights in the domain of volume assessment in critically ill patients. The authors conclude that …
Conclusions: RV failure, defined by critical care echocardiography (RV dilatation) and a surrogate of venous conges‐ tion (CVP ≥ 8 mmHg), was frequently observed in septic shock patients and …
Bench-to-bedside review: An approach to hemodynamic monitoring
Oct 29, 2012 · Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is …
Lactate and stepwise lactate kinetics can be used to guide ...
Oct 27, 2017 · Many studies have demonstrated lower CVP associated with better outcome in sepsis [11, 12]. Thus, after the initial resuscitation, as the lactate kinetics targets were achieved, we tried to …
Venous congestion: are we adding insult to kidney injury in sepsis ...
Jan 27, 2014 · In critical illness, septic shock is a contributing factor in nearly half of all cases of acute kidney injury (AKI). Traditional approaches to prevention of organ dysfunction in early sepsis have …
Dual-lumen catheters for continuous venovenous hemofiltration: limits ...
Feb 15, 2007 · Central venous pressure (CVP) (a) and cardiac output (CO) (b), which are assumed to determine access flow via the arterial line of dual-lumen catheters. (c-f) Biocompatibility parameters …
Hemodynamic monitoring and management in patients undergoing …
Aug 15, 2011 · Introduction Several studies have demonstrated that perioperative hemodynamic optimization has the ability to improve postoperative outcome in high-risk surgical patients. All of …
Cooling and hemodynamic management in heatstroke: practical ...
May 12, 2007 · In the last study, the state of hydration and response to a conservative fluid challenge were prospectively assessed with central venous pressure (CVP) monitoring in 34 consecutive …